Purpose:To evaluate MRI in intraocular foreign bodies as compared with CT as well as conventional X-ray films. Materials and
methods:There were 55 intraocular foreign bodies in 42 patients,33 males and 9 females age ranged from 5~45 years. Fifty-three of the 55 foreign bodies were non-magnetic,and the remaining 2 were ferromagnetic objects. Conventional X-ray films,CT and MRI examinations were accomplished within one month.
Results:(1) The positive rate for showing 55 intraocular foreign bodies was similar on MRI (94%) and CT (91%) (P>0.25),but much higher than conventional X-ray films (42%) (P<0.005);(2) MRI was superior to CT for the demonstration of eye complications related to the foreign bodies,but the contrary was true when they were located within the sclera;(3) T2WI and PDWI of SE sequence were the method of choice for the demonstration of these foreign bodies;(4) non-magnetic foreign bodies usually showed signal loss without artifact on MRI,while ferromagnetic substances produced remarkable artifact and might lead to accidental injury of the eye.
Conclusion:MRI was an effective method for the evaluation of non- magnetic foreign bodies of the eye,especially for the non-metallic foreign bodies undetectable with CT or conventional X-ray film. It was not recommended for ferromagnetic foreign bodies.
Key words:Intraocular foreign bodied Magnetic resonance imaging Tomography,X-ray computed
眼内异物是眼穿孔伤的常见合并症,应尽早取出。其准确定位是手术摘除成败的关键。X线平片、CT和超声是检出眼内异物的重要方法,但均有一定局限性[1]。MRI为眼内异物检出提供了新方法。笔者对42例眼内异物MRI资料进行分析,并与X线平片和CT比较,旨在探讨MRI对眼内异物的诊断价值。 |